Depth of Cure of Composite Using Halogen, LED and Laser

A.M.G. PLEPIS, A.B. DENIS, and M.B. AMARAL, University of São Paulo, São Carlos, Brazil

Objectives: To investigate the efficiency of light sources in the process of photoactivation. The evaluation of the depth of cure of composite-resin was done by two methods: degree of conversion (DC) and Vickers hardness (HV).

Methods: Samples (n=3) 1, 2 and 3mm in thickness were fabricated using Filtek Supreme-3M/ESPE. The groups were polymerized (40s) by: Halogen (Optilux 501/Demetron-Kerr), LED (Lec1000/MMOptics) and Argon laser (Innova100/Coherent) at a setting of 600mW/cm2 and stored (37oC, 24 hours). The DC was measured by Infrared Spectroscopy (FTIR) (Bomem MB-102), using potassium bromide mixed with ground powder of specimens. DC values were determined by using the percentage of carbon double bonds (1638cm-1) present before and after polymerization in comparison with the aromatic peak reference (1608cm-1). For HV, the specimens were measured through Leica VMHT Mot, at (50gf, 30s), making four indentations in the top (1 and 2mm) and bottom (3mm) of the specimens.

Results:

Depth

HALOGEN

LED

LASER

DC% (sd)

HV (sd)

DC% (sd)

HV (sd)

DC% (sd)

HV (sd)

1 mm

39.0 (±1.0)

69.3 (±1.8)

35.6 (±1.1)

68.1 (±0.7)

32.3 (±3.2)

69.2 (±1.0)

2 mm

38.3 (±0.6)

64.8 (±0.2)

35.6 (±2.0)

64.7 (±0.4)

32.0 (±2.6)

66.5 (±1.8)

3 mm

36.3 (±0.6)

54.8 (±0.9)

31.3 (±1.5)

58.4 (±2.1)

27.0 (±1.1)

59.1 (±1.8)

The results were analyzed using two-way analysis of variance and Tukey test. The Pearson's test was used for correlation of the tests (p<0.05).The 3mm presented statistical difference in relation with 1 and 2mm for both tests. The light sources presented statistical differences, in the DC: the Halogen had better values, followed by LED and Argon laser. There was no positive correlation between DC and HV.

Conclusions: All light demonstrated the ability to polymerized the composite, but the Halogen light had better values than the others. The depth of cure decreased significantly in the 3mm.