Valiant PhD-XT Amalgam Delayed-Addition Self-Adhesion Shear-Bond Strength Study
C. ROGGENKAMP, F. BERRY, and H. LU, Loma Linda University, CA, USA | OBJECTIVES: To determine the effects of a reliably consistent
condensation force and dwell time of each condensation stroke on fusing new to
old amalgam.
METHODS: A stabilization jig was implemented holding 15
friction-fit 1” diameter cylindrical resin specimen blocks face up, each with
15/64” wide x 4mm deep wells drilled to contain the condensed substrate Valiant
PhD-XT amalgam. At time intervals of 0-min (Control), 15-min, 60-min, 24-hr, 1
week and 70 days, fresh amalgam was condensed against their razor-blade-shaved substrate
amalgam surfaces through a 3.5mm diameter central hole in a split-ring delrin
disk which served to mold the amalgam test additions. These 15 delrin mold
disks were machined for a friction fit within the 15 holes of the stabilization
jig tray. A consistent, measured force of 4-lb was delivered with a
spring-loaded amalgam carrier adapted with a precision-machined 1 mm-diameter
stainless steel condenser tip. Amalgam button additions were built up in 3
increments with a pattern of eight 4-lb 1-1/2-second condenser thrusts per
layer. MTS shear-bond testing (112-pound load cell and 1-mm/minute crosshead
speed) occurred 24-hr post-condensation. One-way ANOVA statistical analysis
was conducted to analyze the results.
RESULTS: The mean shear-bond forces were not statistically
different from the intact Control group except at 1-hr.
(N = 15 per sample) | Control | 15 min | 1 hr | 1 day | 1 week | 70 days | Mean Shear-Bond Strengths (lbf) | 60.8 | 66.8 | 24.2 | 55.0 | 54.6 | 54.4 |
CONCLUSION: Under the condensation-pressure conditions of this
study, addition of new Valiant PhD-XT amalgam to smooth, previously-set similar-
amalgam surfaces, up to at least 70 days, results in shear-bond strengths not
statistically different from the originally-condensed Controls. Direct reparability
of this type of amalgam under adequate condensation forces appears indicated. Further
studies may elucidate the diminished amalgam-addition receptivity at 1-hr post-trituration.
| Seq #105 - Interface 3:30 PM-4:45 PM, Thursday, July 3, 2008 Metro Toronto Convention Centre Exhibit Hall D-E |
Back to the Dental Materials 1: Adhesion - Bond Strength Testing and Mechanisms Program
|
|